| Software | Software Type | Part Number | Release Date | 
			  
				 | PRISM Series Firmware Release – V5.1.1
					Use this Firmware Release to upgrade from V4.3.1 to V5.1.1. 
					See “Installation Instructions” for details.
					 To upgrade from V4.x (or earlier) to V5.1.1:
					
					  1. Start at V4.2.1 by installing the V4.2.1 image below.2. Upgrade from V4.2.1 to V4.3.1 by installing the V4.3.1 image below.3. Upgrade from V4.3.1 to V5.1.1 by installing the V5.1.1 image above. See “Installation Instructions” for details at each step. PRISM Series Firmware Release – V4.2.1 (Upgrade from V3.5.4 to V4.2.1)
					PRISM Series Firmware Release – V4.3.1 (Upgrade from V4.2.1 to V4.3.1)
					
					Upgrade Compatibility The following 25G products are compatible with this release: 
					  MPI and MPX that have been upgraded to 25GMPI2-10 and MPX2-10 that have been upgraded to 25GMPI2-25 and MPX2-25MPS-100/200/300MPD-100/200/300MPP-100/200/300 NOTE: V5.1.1 is not compatible with: 
						MPI and MPX without 25G upgradeMPI2-10 and MPX2-10 without 25G upgrade The latest software for the incompatible models is the latest V2.x release. New features starting at version 5.1.1 
						3D Look Up TableJPEG XS Test Signal GenerationNMOS 04/05 for GeneratorBanded False colorUpper case support in Hostname | Firmware | P00010785G | 28 March 2025 | 
			    
				  | PRISM Series Firmware Release – V4.3.1 (Update from V4.x to V4.3.1)
					Use this Firmware Release to upgrade from V4.x to V4.3.1. 
					See “Installation Instructions” for details.
					 To upgrade from V3.x (or earlier) to V4.3.1:
					
					  1. Start at V3.5.4 by installing the V3.5.4 image below.2. Upgrade from V3.5.4 to V4.2.1 by installing the V4.2.1 image below.3. Upgrade from V4.2.1 to V4.3.1 by installing the V4.3.1 image above. See “Installation Instructions” for details at each step. PRISM Series Firmware Release – V3.5.4 (Upgrade from V3.x to V3.5.4)
					PRISM Series Firmware Release – V4.2.1 (Upgrade from V3.5.4 to V4.2.1)
					
					Upgrade Compatibility The following 25G products are compatible with this release: 
					  MPI and MPX that have been upgraded to 25GMPI2-10 and MPX2-10 that have been upgraded to 25GMPI2-25 and MPX2-25MPS-100/200/300MPD-100/200/300MPP-100/200/300 NOTE: V4.3.1 is not compatible with: 
						MPI and MPX without 25G upgradeMPI2-10 and MPX2-10 without 25G upgrade The latest software for the incompatible models is the latest V2.x release. New features starting at version 4.3.1 
						JPEG XS decodeMultiple Input IPLuma Qualified CIETSL Tally / UMDAlso includes bug fixes and general improvements for all supported PRISM products. | Firmware | P00010785F | 21 November 2024 | 
              
                | UpgradesThe following 25G products are compatible with this release:
 
                    MPI and MPX that have been upgraded to 25GMPI2-10 and MPX2-10 that have been upgraded to 25GMPI2-25 and MPX2-25MPS-100/200/300MPD-100/200/300MPP-100/200/300 NOTE: V4.2.1 is not compatible with: 
                    MPI and MPX without 25G upgradeMPI2-10 and MPX2-10 without 25G upgrade The latest software for the incompatible models is the latest V2.x release.
                  
                  New features starting at version 4.2.1 
                    2110-43 Timed Text Caption decodeUpto 4 2110-40/43 streamsUpto 8 2110-30/31 streamsStatic NMOS Registry mode2110 IP Display modeVPID over 2110-4032 channel audio over 12G-SDIPicture low latency modeAlso include bug fixes and general improvements for all supported PRISM products. | Firmware Firmware
 | P00010785E P00010070W
 | 7 August 2024 7 August 2024
 | 
              
                | UpgradesThe following 25G products are compatible with this release:
 
                    MPI and MPX that have been upgraded to 25GMPI2-10 and MPX2-10 that have been upgraded to 25GMPI2-25 and MPX2-25MPS-100/200/300MPD-100/200/300MPP-100/200/300 NOTE: V4.1 is not compatible with: 
                    MPI and MPX without 25G upgradeMPI2-10 and MPX2-10 without 25G upgrade The latest software for the incompatible models is the latest V2.x release.
                    
                    New features starting at version 4.1 
                      MPP-100/200/300 Support – MPP is a new, 1RU, full rack width, short depth, waveform monitor
                        that is purposely build for compact and quiet workspaces. In addition to the 12G SDI and 25G IP
                        monitoring tools offered by other PRISM products, MPP offers models that support SDI Eye, always
                        on SDI loop-through, Line Out for external speakers, and 8 channel Analog Audio for mono,
                        stereo, and surround sound outputs.Also include bug fixes and general improvements for all supported PRISM products. Release Notes – V4.1 Installation Instructions | Firmware Firmware
 | P00010785C P00010070U
 | 28 November 2023 28 November 2023
 | 
              
                | PRISM Series Firmware Release
                      – V4.0.1Upgrades The following 25G products are compatible with this release:
 
                    NOTE: V4.0.1 is not compatible with:MPI and MPX that have been upgraded to 25GMPI2-10 and MPX2-10 that have been upgraded to 25GMPI2-25 and MPX2-25MPS-100/200/300MPD-100/200/300 
                    The latest software for the incompatible models is the latest V2.x release.
                  
                  New features starting at version 4.0.1MPI and MPX without 25G upgradeMPI2-10 and MPX2-10 without 25G upgrade 
                    CAM (Camera Alignment Monitoring) - The CAM display allows the user to compare up to four SDI
                      input waveform traces.External Reference Waveform - The External Reference display shows a trace of the currently
                      applied analog reference input.WebRTC - Collaborative real-time Video, Audio, and Control, with the ability to record and
                      download.Aux Out Audio Pair Select - For 2110 inputs, the Aux Out can be configured to remap the audio
                      pair.Vector Compass Rose – Now can add a vector compass rose graticule.Hot Plug HID - Now supports hot plugging control devices. Release Notes – V4.0.1 Installation Instructions | Firmware | P00010070T | 11 September 2023 | 
              
                | PRISM Series Firmware Release
                      – V3.5.4Upgrades The following 25G products are compatible with this release:
 
                    NOTE: V3.5.4 is not compatible with:MPI and MPX that have been upgraded to 25GMPI2-10 and MPX2-10 that have been upgraded to 25GMPI2-25 and MPX2-25MPS-100/200/300MPD-100/200/300 
                    The latest software for the incompatible models is the latest V2.x release.
                  
                  New features starting at version 3.5.2MPI and MPX without 25G upgradeMPI2-10 and MPX2-10 without 25G upgrade 
                    New ST 2110 video monitor and generator formats:
                      
                        2048x1080 4:2:2 YCbCr 10b 23p, 24p, 25p, 29p, 30p4096x2160 4:2:2 YCbCr 10b 23p, 24p, 25p, 29p, 30p1920x1080 4:4:4 RGB 12b 23p, 24p, 25p, 29p, 30p2048x1080 4:4:4 RGB 12b 23p, 24p, 25p, 29p, 30p3840x2160 4:4:4 RGB 12b 23p, 24p, 25p, 29p, 30p4096x2160 4:4:4 RGB 12b 23p, 24p, 25p, 29p, 30pNew HDR, Audio and EBU R103 alarmsNew Immersive PCM audio support for SDI and IP including 5.1.4 / 7.1.4 surround sound display
                    Support for audio programs that are split across multiple ST 2110-30 streamsSupport for dual HDMI receivers on DP ports in MPX2 models. Release Notes – V3.5.4 Installation Instructions | Firmware | P00010070S | 14 April 2023 | 
              
                | PRISM Series Firmware Release
                      – V3.3.3Upgrades The following 25G products are compatible with this release:
 
                    NOTE: V3.3.3 is not compatible with:MPI and MPX that have been upgraded to 25GMPI2-10 and MPX2-10 that have been upgraded to 25GMPI2-25 and MPX2-25MPS-100/200/300MPD-100/200/300 
                    The latest software for the incompatible models is the latest V2.x release.
                  
                  New features since V3.3.2MPI and MPX without 25G upgradeMPI2-10 and MPX2-10 without 25G upgrade 
                    There are no new features or resolved defects in this release. This release is intended for
                      products that have hardware platform changes. See Release Notes for details.  Release Notes – V3.3.3 Installation Instructions | Firmware | P00010070L | 20 September 2022 | 
              
                | PRISM Series Firmware Release
                      – V3.3.2Upgrades The following 25G products are compatible with this release:
 
                    NOTE: V3.3.2 is not compatible with:MPI and MPX that have been upgraded to 25GMPI2-10 and MPX2-10 that have been upgraded to 25GMPI2-25 and MPX2-25MPS-100/200/300MPD-100/200/300 
                    The latest software for the incompatible models is the latest V2.x release.
                  
                  DowngradesMPI and MPX without 25G upgradeMPI2-10 and MPX2-10 without 25G upgrade Downgrading from version 3.x to 2.x is not allowed for the following products due to the hardware
                    configuration:
 
                    New features since V3.1.1MPI2-25 with serial number starting at S010564MPX2-25 with serial number starting at S010386 All MPS/MPD products 
                    Persistent NMOS Receiver with user configurable target input. (Refer to the v3.3.2 User Manual
                      for details)  Release Notes – V3.3.2 Installation Instructions | Firmware | P00010070K | 02 September 2022 | 
              
                | PRISM Series Firmware Release
                    – V3.3.1Upgrades The following 25G products are compatible with this release:
 
                    NOTE: V3.3.1 is not compatible with:MPI and MPX that have been upgraded to 25GMPI2-10 and MPX2-10 that have been upgraded to 25GMPI2-25 and MPX2-25MPS-100/200/300MPD-100/200/300 
                    The latest software for the incompatible models is the latest V2.x release.
                  
                  DowngradesMPI and MPX without 25G upgradeMPI2-10 and MPX2-10 without 25G upgrade Downgrading from version 3.x to 2.x is not allowed for the following products due to the hardware
                    configuration:
 
                    New features since V3.1.1MPI2-25 with serial number starting at S010564MPX2-25 with serial number starting at S010386All MPS/MPD products 
                    New ST 2110 formats:
                      
                        1280x720, 23.98/24/25/29.97/30/50/59.94/60p, YCbCr 4:2:2, 10bit1920x1080, 23.98/24/25/29.97/30p, YCbCr 4:2:2, 10bit2048x1080, 23.98/24/25/29.97/30/50/59.94/60p, YCbCr 4:2:2, 10bit3840x2160, 23.98/24/25/29.97/30/50/59.94/60p, YCbCr 4:2:2, 10bit4096x2160, 23.98/24/25/29.97/30/50/59.94/60p, YCbCr 4:2:2, 10bitNew SDI formats:
                      
                        1280x720, 23.98/24/25/29.97/30/50/59.94/60p, YCbCr 4:2:2, 10bit1920x1080, 23.98/24/29.97/30p, RGB 4:4:4, 12bit2048x1080, 23.98/24/25/29.97/30/47.95/48/50/59.94/60p, YCbCr 4:2:2, 10bit2048x1080, 23.98/24/29.97/30p, RGB 4:4:4, 12bit3840x2160, 23.98/24/29.97/30p, RGB 4:4:4, 12bit4096x2160, 23.98/24/25/29.97/30/47.95/48/50/59.94/60p, YCbCr 4:2:2, 10bit4096x2160, 23.98/24/29.97/30p, RGB 4:4:4, 12bitNew ST 2110 IP Generator formats:
                      
                        1280x720, 23.98/24/25/29.97/30/50/59.94/60p, YCbCr 4:2:2, 10bit1920x1080, 23.98/24/25/29.97/30p, YCbCr 4:2:2, 10bit2048x1080, 23.98/24/25/29.97/30/50/59.94/60p, YCbCr 4:2:2, 10bit3840x2160, 23.98/24/25/29.97/30/50/59.94/60p, YCbCr 4:2:2, 10bit4096x2160, 23.98/24/25/29.97/30/50/59.94/60p, YCbCr 4:2:2, 10bitST 2110-20 fast input switching to improve switching times between IP programsAV Delay Measurement for SDI, ST 2022-6 and ST 2110-20/30/31Dolby E/ED2 Guard Band measurement against house black burst signalDolby ED2 meta data decodingUser configurable Audio Test and Program Peak Level settingAudio channel labeling for 7.1.4Picture Safe Area and AFD graticulesColorized traces in Parade mode for Waveform and Stop displaysFloating Time Code overlay Additional format support for ST 2110-21 Release Notes – V3.3.1 Installation Instructions | Firmware | P00010070J | 25 July 2022 | 
              
                | PRISM Series Firmware Release
                      – V3.1.1Upgrades The following 25G products are compatible with this release:
 
                    NOTE: V3.1.1 is not compatible with:MPI and MPX that have been upgraded to 25G MPI2-10 and MPX2-10 that have been upgraded to 25G MPI2-25 and MPX2-25 MPS-100/200/300 MPD-100/200/300  
                    The latest software version for the incompatible models is V2.3.1.
                  
                  Downgrades MPI and MPX without 25G upgrade MPI2-10 and MPX2-10 without 25G upgrade  Downgrading from version 3.x to 2.x is not allowed for the following products due to the hardware
                    configuration:
 
                    New features since V3.0MPI2-25 with serial number starting at S010564 MPX2-25 with serial number starting at S010386 All MPS/MPD products 
                    Multi SDI Input Mode
                      
                        Up to four 4K 6/12G SDI inputs can be simultaneously monitored with picture and trace
                          applications (waveform, stop, vector, CIE). 
                     NMOS IS-04 v1.3
                      
                        IS-04 v1.2 or v1.3 can be selected 
                    GPI Preset Recall
                      
                        Up to 6 presets can be recalled through GPIO connector. 
                    SDI Loop-through
                      
                        SDI 1 and SDI 2 input signal can be output from SDI 3 and SDI 4 respectively. 
                    New features since V2.3.1 and V2.4 (In addition to the new features from V3.0)Headless remote operation using VNC for MPX2 mode
                      
                        Remote 8 tile operation using VNC in 8 tile mode is supported without the need for an
                          external monitor or monitor emulator attached.Note: MPI2 and MPS models still require an external monitor or monitor emulator for remote
                          operation using VNC in 8 tile mode. 
                    MPS/MPD model support8 trace Tile/Dual Display including eight 4K trace tiles
                      
                        8 trace tiles display is supported with dual display configuration.Trace applications with 4K signals could be assigned to any tile. 
                    ARIB Closed Caption decode
                      
                        ARIB TR-B24 standard is supported to decode.HD/SD/Mobile captions can be simultaneously decoded. 
                    AES Status Display for SDI
                      
                        AES/EBU header information in SDI embedded audio can be displayed. 
                    YCbCr 4:2:2 1080p 23/24/25/29/30 over 2110-20
                      
                        Slow frame 422 formats over ST 2110-20 are added. 
                    PTP time display on Status Bar
                      